Feed/CVE-2019-15800
CVE-2019-15800CRITICALCVSS 9.8

CVE-2019-15800

Published Nov 14, 2019·Updated Jun 16, 2026

NVD Description

An issue was discovered on Zyxel GS1900 devices with firmware before 2.50(AAHH.0)C0. Due to lack of input validation in the cmd_sys_traceroute_exec(), cmd_sys_arp_clear(), and cmd_sys_ping_exec() functions in the libclicmd.so library contained in the firmware, an attacker could leverage these functions to call system() and execute arbitrary commands on the switches. (Note that these functions are currently not called in this version of the firmware, however an attacker could use other vulnerabilities to finally use these vulnerabilities to gain code execution.)

CVSS Vector

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H