Atom.CMS 2.0 is vulnerable to SQL Injection via Atom.CMS_admin_uploads.php
AtomCMS 2.0 is vulnerable to SQL Injection via Atom.CMS_admin_ajax_pages.php
SQL injection vulnerability in Topics Searching feature of Roothub 2.6.0 allows unauthorized attackers to execute arbitrary SQL commands via the "s" parameter remotely.
SQL injection vulnerability in Topics Counting feature of Roothub 2.6.0 allows unauthorized attackers to execute arbitrary SQL commands via the "s" parameter remotely.
CSZ CMS 1.2.2 is vulnerable to SQL Injection via cszcms_admin_Plugin_manager_setstatus
CSZ CMS 1.2.2 is vulnerable to SQL Injection via cszcms_admin_Users_viewUsers
CSZ CMS 1.2.2 is vulnerable to SQL Injection via cszcms_admin_Users_editUser
CSZ CMS 1.2.2 is vulnerable to SQL Injection via cszcms_admin_Members_editUser
Csz Cms 1.2.2 is vulnerable to SQL Injection via cszcms_admin_Members_viewUsers
The fix issued for CVE-2020-17530 was incomplete. So from Apache Struts 2.0.0 to 2.5.29, still some of the tag’s attributes could perform a double evaluation if a developer applied forced OGNL evaluation by using the %{...} syntax. Using forced OGNL evaluation on untrusted user input can lead to a Remote Code Execution and security degradation.
The Visual Form Builder WordPress plugin before 3.0.8 is vulnerable to CSV injection allowing a user with low level or no privileges to inject a command that will be included in the exported CSV file, leading to possible code execution.
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V),
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). The affected system allows remote users to send maliciously crafted objects. Due to insecure deserialization of user-supplied content by the affected software, an unauthenticated attacker could exploit this vulnerability by sending a maliciously crafted serialized object. This could allow the attacker to execute arbitrary code on the devic
The npm-dependency-versions package through 0.3.0 for Node.js allows command injection if an attacker is able to call dependencyVersions with a JSON object in which pkgs is a key, and there are shell metacharacters in a value.
A SQL injection issue was discovered in QuerySet.explain() in Django 2.2 before 2.2.28, 3.2 before 3.2.13, and 4.0 before 4.0.4. This occurs by passing a crafted dictionary (with dictionary expansion) as the **options argument, and placing the injection payload in an option name.
An issue was discovered in Django 2.2 before 2.2.28, 3.2 before 3.2.13, and 4.0 before 4.0.4. QuerySet.annotate(), aggregate(), and extra() methods are subject to SQL injection in column aliases via a crafted dictionary (with dictionary expansion) as the passed **kwargs.
The vulnerability in the MSC800 in all versions before 4.15 allows for an attacker to predict the TCP initial sequence number. When the TCP sequence is predictable, an attacker can send packets that are forged to appear to come from a trusted computer. These forged packets could compromise services on the MSC800. SICK has released a new firmware version of the SICK MSC800 and recommends updating to the newest version.
VMware Workspace ONE Access and Identity Manager contain a remote code execution vulnerability due to server-side template injection. A malicious actor with network access can trigger a server-side template injection that may result in remote code execution.
The Wi-Fi module has an event notification vulnerability.Successful exploitation of this vulnerability may allow third-party applications to intercept event notifications and add information and result in elevation-of-privilege.
An attacker with the ability to modify a user program may change user program code on some ControlLogix, CompactLogix, and GuardLogix Control systems. Studio 5000 Logix Designer writes user-readable program code to a separate location than the executed compiled code, allowing an attacker to change one and not the other.