A Buffer Overflow vulnerability exists in TP-LINK WR-886N 20190826 2.3.8 in the /cloud_config/router_post/get_reset_pwd_veirfy_code feature, which allows malicious users to execute arbitrary code on the system via a crafted post request.
A Buffer Overflow vulnerability exists in TP-LINK WR-886N 20190826 2.3.8 in the /cloud_config/router_post/get_reset_pwd_veirfy_code feature, which allows malicious users to execute arbitrary code on the system via a crafted post request.
A Buffer Overflow vulnerability exists in TP-LINK WR-886N 20190826 2.3.8 in the /cloud_config/router_post/get_reg_verify_code feature, which allows malicious users to execute arbitrary code on the system via a crafted post request.
A Buffer Overflow vulnerability exists in TP-LINK WR-886N 20190826 2.3.8 in /cloud_config/cloud_device/info interface, which allows a malicious user to executee arbitrary code on the system via a crafted post request.
A Buffer Overflow vulnerability exists in TP-LINK WR-886N 20190826 2.3.8 via the /cloud_config/router_post/check_reset_pwd_verify_code interface.
A Buffer Overflow vulnerability exists in TP-LINK WR-886N 20190826 2.3.8 in the /cloud_config/router_post/check_reg_verify_code function which could let a remove malicious user execute arbitrary code via a crafted post request.
It was discovered that the SteelCentral AppInternals Dynamic Sampling Agent's (DSA) PluginServlet has directory traversal vulnerabilities at the "/api/appInternals/1.0/plugin/pmx" API. The affected endpoint does not have any input validation of the user's input that allows a malicious payload to be injected.
It was discovered that the SteelCentral AppInternals Dynamic Sampling Agent's (DSA) AgentDiagnosticServlet has directory traversal vulnerability at the "/api/appInternals/1.0/agent/diagnostic/logs" API. The affected endpoint does not have any input validation of the user's input that allows a malicious payload to be injected.
It was discovered that the SteelCentral AppInternals Dynamic Sampling Agent's (DSA) AgentConfigurationServlet has directory traversal vulnerabilities at the "/api/appInternals/1.0/agent/configuration" API. The affected endpoint does not have any input validation of the user's input that allows a malicious payload to be injected.
It was discovered that the SteelCentral AppInternals Dynamic Sampling Agent (DSA) has Remote Code Execution vulnerabilities in multiple instances of the API requests. The affected endpoints do not have any input validation of the user's input that allowed a malicious payload to be injected.
There is a permission control vulnerability in the Nearby module.Successful exploitation of this vulnerability will affect availability and integrity.
There is an out-of-bounds read vulnerability in the IFAA module. Successful exploitation of this vulnerability may cause stack overflow.
Panorama Tools libpano13 v2.9.20 was discovered to contain an out-of-bounds read in the function panoParserFindOLine() in parser.c.
A command injection vulnerability exists in the Xiaomi Router AX3600. The vulnerability is caused by a lack of inspection for incoming data detection. Attackers can exploit this vulnerability to execute code.
Static Code Injection in GitHub repository microweber/microweber prior to 1.3.
A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause an unauthenticated connection to the UPS when a malformed connection is sent. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior
A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists that could cause remote code execution when an improperly handled TLS packet is reassembled. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series
A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and used to upload malicious firmware. Affected Product: APC Smart-UPS Family: SMT Series (SMT Series ID=18: UPS 09.8 and prior / SMT Series ID=1040: UPS 01.2 and prior / SMT Series ID=1031: UPS 03.1 and prior), SMC Series (SMC Series ID=1005: UPS 14.1 and prior / SMC Series ID=1007: UPS 11.0 and prior / SMC Series ID=1041: UPS 01.1 and prior), S
Exposure of Private Personal Information to an Unauthorized Actor in GitHub repository alextselegidis/easyappointments prior to 1.4.3.
A vulnerability has been identified in Mendix Forgot Password Appstore module (All versions >= V3.3.0 < V3.5.1), Mendix Forgot Password Appstore module (Mendix 7 compatible) (All versions < V3.2.2). Initial passwords are generated in an insecure manner. This could allow an unauthenticated remote attacker to efficiently brute force passwords in specific situations.
A vulnerability has been identified in Mendix Forgot Password Appstore module (All versions >= V3.3.0 < V3.5.1). In certain configurations of the affected product, a threat actor could use the sign up flow to hijack arbitrary user accounts.