A vulnerability was found in Portainer before 1.20.0. Portainer stores LDAP credentials, corresponding to a master password, in cleartext and allows their retrieval via API calls.
A potential vulnerability has been identified in HP Remote Graphics Software’s certificate authentication process version 7.5.0 and earlier.
In HP LaserJet Enterprise, HP PageWide Enterprise, HP LaserJet Managed, and HP OfficeJet Enterprise Printers, solution application signature checking may allow potential execution of arbitrary code.
Due to the use of an insecure algorithm for rolling codes in the ABUS Secvest wireless alarm system FUAA50000 3.01.01 and its remote controls FUBE50014 and FUBE50015, an attacker is able to predict valid future rolling codes, and can thus remotely control the alarm system in an unauthorized way.
A remote code execution vulnerability in development mode Rails <5.2.2.1, <6.0.0.beta3 can allow an attacker to guess the automatically generated development mode secret token. This secret token can be used in combination with other Rails internals to escalate to a remote code execution exploit.
There is a File Content Disclosure vulnerability in Action View <5.2.2.1, <5.1.6.2, <5.0.7.2, <4.2.11.1 and v3 where specially crafted accept headers can cause contents of arbitrary files on the target system's filesystem to be exposed.
An issue was discovered in aio_poll() in fs/aio.c in the Linux kernel through 5.0.4. A file may be released by aio_poll_wake() if an expected event is triggered immediately (e.g., by the close of a pair of pipes) after the return of vfs_poll(), and this will cause a use-after-free.
The monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port into the mirrored network. An attacker could use this behavior to transmit malicious packets to systems in the mirrored network, possibly influencing their configuration and runtime behavior.
An issue was discovered in Kentico 12.0.x before 12.0.15, 11.0.x before 11.0.48, 10.0.x before 10.0.52, and 9.x versions. Due to a failure to validate security headers, it was possible for a specially crafted request to the staging service to bypass the initial authentication and proceed to deserialize user-controlled .NET object input. This deserialization then led to unauthenticated remote code execution on the server where the Kentico instance was hosted.
The potential exists for exposure of the product's password used to restrict unauthorized access to Rockwell PLC5/SLC5/0x/RSLogix 1785-Lx and 1747-L5x controllers. The potential exists for an unauthorized programming and configuration client to gain access to the product and allow changes to the product’s configuration or program. When applicable, upgrade product firmware to a version that includes enhanced security functionality compatible with Rockwell Automation's FactoryTalk Security service
Hospira MedNet software version 5.8 and prior uses vulnerable versions of the JBoss Enterprise Application Platform software that may allow unauthenticated users to execute arbitrary code on the target system. Hospira has developed a new version of the MedNet software, MedNet 6.1. Existing versions of MedNet can be upgraded to MedNet 6.1.
An unauthenticated remote attacker may be able to execute commands to view wireless account credentials that are stored in cleartext on Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16, which may allow an attacker to gain access the host network. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes.
Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 is remotely accessible via Port 22/SSH without authentication. A remote attacker may be able to make unauthorized configuration changes to the WBM, as well as issue commands to access account credentials and shared keys. Baxter asserts that this vulnerability only allows access to features and functionality on the WBM and that the SIGMA Spectrum infusion pump cannot be controlled fro
Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 has a default account with hard-coded credentials used with the FTP protocol. Baxter asserts no files can be transferred to or from the WBM using this account. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes.
Flatpak before 1.0.8, 1.1.x and 1.2.x before 1.2.4, and 1.3.x before 1.3.1 allows a sandbox bypass. Flatpak versions since 0.8.1 address CVE-2017-5226 by using a seccomp filter to prevent sandboxed apps from using the TIOCSTI ioctl, which could otherwise be used to inject commands into the controlling terminal so that they would be executed outside the sandbox after the sandboxed app exits. This fix was incomplete: on 64-bit platforms, the seccomp filter could be bypassed by an ioctl request num
tls1.c in Cameron Hamilton-Rich axTLS before 2.1.5 has a Buffer Overflow via a crafted sequence of TLS packets because the need_bytes value is mismanaged.
An issue was discovered in Interpeak IPWEBS on Green Hills INTEGRITY RTOS 5.0.4. It allocates 60 bytes for the HTTP Authentication header. However, when copying this header to parse, it does not check the size of the header, leading to a stack-based buffer overflow.
An issue was discovered in the Interpeak IPCOMShell TELNET server on Green Hills INTEGRITY RTOS 5.0.4. There is a heap-based buffer overflow in the function responsible for printing the shell prompt, when a custom modifier is used to display information such as a process ID, IP address, or current working directory. Modifier expansion triggers this overflow, causing memory corruption or a crash (and also leaks memory address information).
utils/find-opencv.js in node-opencv (aka OpenCV bindings for Node.js) prior to 6.1.0 is vulnerable to Command Injection. It does not validate user input allowing attackers to execute arbitrary commands.
The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement authentication or authorization. An attacker with adjacent