The (1) order and (2) group methods in Zend_Db_Select in the Zend Framework before 1.12.19 might allow remote attackers to conduct SQL injection attacks via vectors related to use of the character pattern [\w]* in a regular expression.
The (1) order and (2) group methods in Zend_Db_Select in the Zend Framework before 1.12.19 might allow remote attackers to conduct SQL injection attacks via vectors related to use of the character pattern [\w]* in a regular expression.
The (1) order and (2) group methods in Zend_Db_Select in the Zend Framework before 1.12.20 might allow remote attackers to conduct SQL injection attacks by leveraging failure to remove comments from an SQL statement before validation.
SQL injection vulnerability in Zabbix before 2.2.14 and 3.0 before 3.0.4 allows remote attackers to execute arbitrary SQL commands via the toggle_ids array parameter in latest.php.
IBM Integration Bus 9.0 and 10.0 and WebSphere Message Broker SOAP FLOWS is vulnerable to a denial of service, caused by an XML External Entity Injection (XXE) error when processing XML data. A remote attacker could exploit this vulnerability to expose highly sensitive information or consume all available memory resources. IBM Reference #: 1997918.
Multiple SQL injection vulnerabilities in modified eCommerce Shopsoftware 2.0.0.0 revision 9678, when the easybill-module is not installed, allow remote attackers to execute arbitrary SQL commands via the (1) orders_status or (2) customers_status parameter to api/easybill/easybillcsv.php.
IBM Websphere MQ JMS 7.0.1, 7.1, 7.5, 8.0, and 9.0 client provides classes that deserialize objects from untrusted sources which could allow a malicious user to execute arbitrary Java code by adding vulnerable classes to the classpath. IBM Reference #: 1983457.
Heap-based buffer overflow in the ALGnew function in block_templace.c in Python Cryptography Toolkit (aka pycrypto) allows remote attackers to execute arbitrary code as demonstrated by a crafted iv parameter to cryptmsg.py.
Adobe Digital Editions versions 4.5.3 and earlier have an exploitable heap overflow vulnerability. Successful exploitation could lead to arbitrary code execution.
Adobe Campaign versions 16.4 Build 8724 and earlier have a code injection vulnerability.
An issue was discovered in Smiths-Medical CADD-Solis Medication Safety Software, Version 1.0; 2.0; 3.0; and 3.1. CADD-Solis Medication Safety Software grants an authenticated user elevated privileges on the SQL database, which would allow an authenticated user to modify drug libraries, add and delete users, and change user permissions. According to Smiths-Medical, physical access to the pump is required to install drug library updates.
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. An INFORMATION EXPOSURE flaw can be used to gain privileged access to the device.
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Lack of authentication for remote service gives access to application set up and configuration.
An issue was discovered on Phoenix Contact mGuard devices that have been updated to Version 8.4.0. When updating an mGuard device to Version 8.4.0 via the update-upload facility, the update will succeed, but it will reset the password of the admin user to its default value.
An issue was discovered in Advantech WebAccess Version 8.1. To be able to exploit the SQL injection vulnerability, an attacker must supply malformed input to the WebAccess software. Successful attack could result in administrative access to the application and its data files.
An issue was discovered in Advantech WebAccess Version 8.1. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access pages unrestricted (AUTHENTICATION BYPASS).
An issue was discovered in Carlo Gavazzi VMU-C EM prior to firmware Version A11_U05, and VMU-C PV prior to firmware Version A17. Successful exploitation of this CROSS-SITE REQUEST FORGERY (CSRF) vulnerability can allow execution of unauthorized actions on the device such as configuration parameter changes, and saving modified configuration.
An issue was discovered in Carlo Gavazzi VMU-C EM prior to firmware Version A11_U05, and VMU-C PV prior to firmware Version A17. The access control flaw allows access to most application functions without authentication.
An issue was discovered in Honeywell XL Web II controller XL1000C500 XLWebExe-2-01-00 and prior, and XLWeb 500 XLWebExe-1-02-08 and prior. A user with low privileges is able to open and change the parameters by accessing a specific URL because of Improper Privilege Management.
An issue was discovered in Honeywell XL Web II controller XL1000C500 XLWebExe-2-01-00 and prior, and XLWeb 500 XLWebExe-1-02-08 and prior. Password is stored in clear text.
An issue was discovered in Honeywell XL Web II controller XL1000C500 XLWebExe-2-01-00 and prior, and XLWeb 500 XLWebExe-1-02-08 and prior. Any user is able to disclose a password by accessing a specific URL, because of Plaintext Storage of a Password.