Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in Alexandre Froger WP Weixin wp-weixin allows Stored XSS.This issue affects WP Weixin: from n/a through <= 1.3.16.
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in Alexandre Froger WP Weixin wp-weixin allows Stored XSS.This issue affects WP Weixin: from n/a through <= 1.3.16.
Missing authorization in Ivanti Connect Secure before 22.7R2.9 or 22.8R2, Ivanti Policy Secure before 22.7R1.6, Ivanti ZTA Gateway before 22.8R2.3-723 and Ivanti Neurons for Secure Access before 22.8R1.4 (Fix deployed on 02-Aug-2025) allows a remote authenticated attacker with read-only admin privileges to configure restricted settings.
CSRF in Ivanti Connect Secure before 22.7R2.9 or 22.8R2, Ivanti Policy Secure before 22.7R1.6, Ivanti ZTA Gateway before 2.8R2.3-723 and Ivanti Neurons for Secure Access before 22.8R1.4 (Fix deployed on 02-Aug-2025) allows a remote unauthenticated attacker to execute limited actions on behalf of the victim user. User interaction is required.
An unchecked return value in Ivanti Connect Secure before 22.7R2.9 or 22.8R2, Ivanti Policy Secure before 22.7R1.6, Ivanti ZTA Gateway before 2.8R2.3-723 and Ivanti Neurons for Secure Access before 22.8R1.4 (Fix deployed on 02-Aug-2025) allows a remote authenticated attacker with admin privileges to trigger a denial of service.
Missing authorization in Ivanti Connect Secure before 22.7R2.9 or 22.8R2, Ivanti Policy Secure before 22.7R1.6, Ivanti ZTA Gateway before 2.8R2.3-723 and Ivanti Neurons for Secure Access before 22.8R1.4 (Fix deployed on 02-Aug-2025) allows a remote authenticated attacker with read-only admin privileges to configure restricted settings.
Reflected text injection in Ivanti Connect Secure before 22.7R2.9 or 22.8R2, Ivanti Policy Secure before 22.7R1.6, Ivanti ZTA Gateway before 2.8R2.3-723 and Ivanti Neurons for Secure Access before 22.8R1.4 (Fix deployed on 02-Aug-2025) allows a remote unauthenticated attacker to inject arbitrary text into a crafted HTTP response. User interaction is required.
SSRF in Ivanti Connect Secure before 22.7R2.9 or 22.8R2, Ivanti Policy Secure before 22.7R1.6, Ivanti ZTA Gateway before 2.8R2.3-723 and Ivanti Neurons for Secure Access before 22.8R1.4 (Fix deployed on 02-Aug-2025) allows a remote authenticated attacker with admin privileges to enumerate internal services.
A Stored cross-site scripting vulnerability in the Liferay Portal 7.4.0 through 7.4.3.132, and Liferay DXP 2025.Q2.0 through 2025.Q2.9, 2025.Q1.0 through 2025.Q1.16, 2024.Q4.0 through 2024.Q4.7, 2024.Q3.0 through 2024.Q3.13, 2024.Q2.0 through 2024.Q2.13, 2024.Q1.1 through 2024.Q1.19 and 7.4 GA through update 92 allows an remote authenticated attacker to inject JavaScript through Custom Object field label. The malicious payload is stored and executed through Process Builder's Configuration tab w
A vulnerability has been found in TRENDnet TEW-831DR 1.0 (601.130.1.1410). Impacted is an unknown function of the file /boafrm/formSysCmd. The manipulation of the argument sysHost leads to command injection. The attack is possible to be carried out remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A Relative Path Traversal vulnerability [CWE-23] in FortiWeb 7.6.0 through 7.6.4, 7.4.0 through 7.4.8, 7.2.0 through 7.2.11, 7.0.2 through 7.0.11 may allow an authenticated attacker to perform an arbitrary file read on the underlying system via crafted requests.
An improper neutralization of special elements used in an OS command ('OS Command Injection') vulnerabilities [CWE-78] in Fortinet FortiDDoS-F version 7.0.0 through 7.02 and before 6.6.3 may allow a privileged attacker to execute unauthorized code or commands via crafted CLI requests.
A security issue exists in the protected mode of EN4TR devices, where sending specifically crafted messages during a Forward Close operation can cause the device to crash.
A security issue exists in the protected mode of 1756-EN4TR and 1756-EN2TR communication modules, where a Concurrent Forward Close operation can trigger a Major Non-Recoverable (MNFR) fault. This condition may lead to unexpected system crashes and loss of device availability.
Missing authorization checks in the CSV download feature of TYPO3 CMS versions 11.0.0‑11.5.47, 12.0.0‑12.4.36, and 13.0.0‑13.4.17 allow backend users to disclose information from arbitrary database tables stored within the users' web mounts without having access to them.
Missing authorization checks in the Workspace Module of TYPO3 CMS versions 9.0.0‑9.5.54, 10.0.0‑10.4.53, 11.0.0‑11.5.47, 12.0.0‑12.4.36, and 13.0.0‑13.4.17 allow backend users to directly invoke the corresponding AJAX backend route to disclose sensitive information without having access.
Error messages containing sensitive information in the File Abstraction Layer in TYPO3 CMS versions 9.0.0-9.5.54, 10.0.0-10.4.53, 11.0.0-11.5.47, 12.0.0-12.4.36, and 13.0.0-13.4.17 allow backend users to disclose full file paths via failed low-level file-system operations.
A deterministic three‑character prefix in the Password Generation component of TYPO3 CMS versions 12.0.0–12.4.36 and 13.0.0–13.4.17 reduces entropy, allowing attackers to carry out brute‑force attacks more quickly.
An open‑redirect vulnerability in GeneralUtility::sanitizeLocalUrl of TYPO3 CMS 9.0.0–9.5.54, 10.0.0–10.4.53, 11.0.0–11.5.47, 12.0.0–12.4.36, and 13.0.0–13.4.17 allows an attacker to redirect users to arbitrary external sites, enabling phishing attacks by supplying a manipulated, sanitized URL.
A vulnerability has been identified in APOGEE PXC Series (BACnet) (All versions), APOGEE PXC Series (P2 Ethernet) (All versions), TALON TC Series (BACnet) (All versions). Affected devices connected to the network allow unrestricted access to sensitive files, such as databases. This could allow an attacker to download encrypted .db file containing passwords.
A vulnerability has been identified in SINAMICS G220 V6.4 (All versions < V6.4 HF2), SINAMICS S200 V6.4 (All versions < V6.4 HF7), SINAMICS S210 V6.4 (All versions < V6.4 HF2). The affected devices allow a factory reset to be executed without the required privileges due to improper privilege management as well as manipulation of configuration data because of leaked privileges of previous sessions. This could allow an unauthorized attacker to escalate their privileges.