In OpENer 2.3.0 (commit 76b95cf) when parsing incoming CIP (Common Industrial Protocol) network packets, the length parameter is inconsistently typed across the call stack. Specifically, an upstream length calculated as an int is passed to a downstream function that expects an EipInt16 (a 16-bit signed integer). If a maliciously crafted packet with specific length fields is processed, the length parameter can overflow or be truncated into a negative value. This negative length bypasses subsequen