OX App Suite through 7.10.6 allows OS Command Injection via a serialized Java class to the Documentconverter API.
OX App Suite through 7.10.6 allows OS Command Injection via Documentconverter (e.g., through an email attachment).
An authentication bypass vulnerability in Skyhigh SWG in main releases 10.x prior to 10.2.12, 9.x prior to 9.2.23, 8.x prior to 8.2.28, and controlled release 11.x prior to 11.2.1 allows a remote attacker to bypass authentication into the administration User Interface. This is possible because of SWG incorrectly whitelisting authentication bypass methods and using a weak crypto password. This can lead to the attacker logging into the SWG admin interface, without valid credentials, as the super u
HashiCorp Vault Enterprise 1.7.0 through 1.9.7, 1.10.4, and 1.11.0 clusters using Integrated Storage expose an unauthenticated API endpoint that could be abused to override the voter status of a node within a Vault HA cluster, introducing potential for future data loss or catastrophic failure. Fixed in Vault Enterprise 1.9.8, 1.10.5, and 1.11.1.
The Motorola ACE1000 RTU through 2022-05-02 uses ECB encryption unsafely. It can communicate with an XRT LAN-to-radio gateway by means of an embedded client. Credentials for accessing this gateway are stored after being encrypted with the Tiny Encryption Algorithm (TEA) in ECB mode using a hardcoded key. Similarly, the ACE1000 RTU can route MDLC traffic over Extended Command and Management Protocol (XCMP) and Network Layer (XNL) networks via the MDLC driver. Authentication to the XNL port is pro
The Motorola ACE1000 RTU through 2022-05-02 ships with a hardcoded SSH private key and initialization scripts (such as /etc/init.d/sshd_service) only generate a new key if no private-key file exists. Thus, this hardcoded key is likely to be used by default.
The Motorola ACE1000 RTU through 2022-05-02 has default credentials. It exposes an SSH interface on port 22/TCP. This interface is used for remote maintenance and for SFTP file-transfer operations that are part of engineering software functionality. Access to this interface is controlled by 5 preconfigured accounts (root, abuilder, acelogin, cappl, ace), all of which come with default credentials. Although the ACE1000 documentation mentions the root, abuilder and acelogin accounts and instructs
The Omron SYSMAC Cx product family PLCs (CS series, CJ series, and CP series) through 2022-05-18 lack cryptographic authentication. They utilize the Omron FINS (9600/TCP) protocol for engineering purposes, including downloading projects and control logic to the PLC. This protocol has authentication flaws as reported in FSCT-2022-0057. Control logic is downloaded to PLC volatile memory using the FINS Program Area Read and Program Area Write commands or to non-volatile memory using other commands
The Omron SYSMAC Nx product family PLCs (NJ series, NY series, NX series, and PMAC series) through 2022-005-18 lack cryptographic authentication. These PLCs are programmed using the SYMAC Studio engineering software (which compiles IEC 61131-3 conformant POU code to native machine code for execution by the PLC's runtime). The resulting machine code is executed by a runtime, typically controlled by a real-time operating system. The logic that is downloaded to the PLC does not seem to be cryptogra
The Motorola MDLC protocol through 2022-05-02 mishandles message integrity. It supports three security modes: Plain, Legacy Encryption, and New Encryption. In Legacy Encryption mode, traffic is encrypted via the Tiny Encryption Algorithm (TEA) block-cipher in ECB mode. This mode of operation does not offer message integrity and offers reduced confidentiality above the block level, as demonstrated by an ECB Penguin attack against any block ciphers.
JTEKT TOYOPUC PLCs through 2022-04-29 do not ensure data integrity. They utilize the unauthenticated CMPLink/TCP protocol for engineering purposes, including downloading projects and control logic to the PLC. Control logic is downloaded to the PLC on a block-by-block basis with a given memory address and a blob of machine code. The logic that is downloaded to the PLC is not cryptographically authenticated, allowing an attacker to execute arbitrary machine code on the PLC's CPU module in the cont
The Bently Nevada 3700 series of condition monitoring equipment through 2022-04-29 has a maintenance interface on port 4001/TCP with undocumented, hardcoded credentials. An attacker capable of connecting to this interface can thus trivially take over its functionality.
Bently Nevada condition monitoring equipment through 2022-04-29 mishandles authentication. It utilizes the TDI command and data protocols (60005/TCP, 60007/TCP) for communications between the monitoring controller and System 1 and/or Bently Nevada Monitor Configuration (BNMC) software. These protocols provide configuration management and historical data related functionality. Neither protocol has any authentication features, allowing any attacker capable of communicating with the ports in questi
JTEKT TOYOPUC PLCs through 2022-04-29 mishandle authentication. They utilize the CMPLink/TCP protocol (configurable on ports 1024-65534 on either TCP or UDP) for a wide variety of engineering purposes such as starting and stopping the PLC, downloading and uploading projects, and changing configuration settings. This protocol does not have any authentication features, allowing any attacker capable of communicating with the port in question to invoke (a subset of) desired functionality.
Type confusion in V8 Turbofan in Google Chrome prior to 100.0.4896.127 allowed a remote attacker to potentially exploit heap corruption via a crafted HTML page.
In Zoho ManageEngine SupportCenter Plus before 11023, V3 API requests are vulnerable to authentication bypass. (An API request may, in effect, be executed with the credentials of a user who authenticated in the past.)
Orange Station 1.0 was discovered to contain a SQL injection vulnerability via the username parameter.
Fruits Bazar v1.0 was discovered to contain a SQL injection vulnerability via the recover_email parameter at user_password_recover.php.
A vulnerability in adm.cgi of WAVLINK WN535 G3 M35G3R.V5030.180927 allows attackers to execute arbitrary code via a crafted POST request.
Joplin v2.8.8 allows attackers to execute arbitrary commands via a crafted payload injected into the Node titles.